APC Back-UPS BE650G2-UK
UPS | AC 230 V | 400 watt | 650 VA | output connectors: 8 | United Kingdom | black
Main Specification
| Product Description | APC Back-UPS BE650G2-UK - UPS - 400 watt - 650 VA |
|---|---|
| Device Type | UPS - external |
| Weight | 4 kg |
| Localisation | United Kingdom |
| Input Voltage | AC 230 V |
| Output Voltage | AC 230 V |
| Power Capacity | 400 watt / 650 VA |
| Input Connectors | 1 x power BS 1363A |
| Output connectors | 6 x power (UPS and surge) 2 x power (surge) 1 x 4 pin USB Type A 2.4 A |
| Battery | Lead Acid |
| Batteries Qty | 1 |
| Run Time (Up To) | 2.6 min at full load |
| Colour | Black |
| Dimensions (WxDxH) | 13 cm x 36.5 cm x 12 cm |
| Manufacturer Warranty | 3-year warranty |
General
| Device Type | UPS - external |
|---|---|
| Colour | Black |
| Localisation | United Kingdom |
Power Device
| Input Voltage | AC 230 V |
|---|---|
| Input Voltage Range | AC 180 - 266 V |
| Frequency Provided | 50/60 Hz |
| Frequency Required | 47 - 63 Hz |
| Input Connectors | 1 x power BS 1363A |
| Power Output Connectors Details | 6 x power (UPS and surge) 2 x power (surge) 1 x 4 pin USB Type A 2.4 A |
| Output Voltage | AC 230 V 50/60 Hz |
| Power Capacity | 400 watt / 650 VA |
| Dataline Surge Protection | Network - RJ-45 |
| Output Waveform | Stepped approximation to a sinewave |
| Surge Suppression | Yes |
| Surge Energy Rating | 310 joules |
| Circuit Protection | Circuit breaker |
| Efficiency | 80% |
Battery
| Quantity | 1 |
|---|---|
| Technology | Lead Acid |
| Run Time (Up To) | 56.2 min at 50 Watts 26 min at 100 Watts 10.4 min at 200 Watts 5.2 min at 300 Watts 2.6 min at 400 Watts |
| Recharge Time | 16 hours |
| Transfer Time | 6 ms |
| Features | Maintenance free, sealed |
Miscellaneous
| Cables Included | Power cable 1.83 m |
|---|---|
| Features | Audible alarm, overload protection |
| Compliant Standards | IP20 |
Software / System Requirements
| Software Included | APC PowerChute Personal Edition |
|---|
Manufacturer Warranty
| Service & Support | Limited warranty - 3 years |
|---|
Environmental Parameters
| Min Operating Temperature | 0 °C |
|---|---|
| Max Operating Temperature | 40 °C |
| Humidity Range Operating | 0 - 95% (non-condensing) |
Dimensions & Weight
| Width | 13 cm |
|---|---|
| Depth | 36.5 cm |
| Height | 12 cm |
| Weight | 4 kg |
Dimensions & Weight (Shipping)
| Shipping Width | 18.6 cm |
|---|---|
| Shipping Depth | 44.1 cm |
| Shipping Height | 19 cm |
| Shipping Weight | 4.5 kg |
Product features
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Compact design fits comfortably in short-depth rack applications.
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.Battery charging indicator
Lets you know when your battery is charging and when it is fully charged.Disconnected battery notification
Warns when a battery is not available to provide backup power. Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Provides notification of changing utility power and UPS power conditions
Delivers higher availability through redundant batteries. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipmentBattery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment Provides temporary battery power when the utility power is out. Reduces cord clutter. Provides protection of connected equipment from power surges on the data lines. Ensures clean, uninterrupted power to protected equipment while batteries are being replacedHot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replacedProvides early-warning fault analysis on batteries enabling timely preventive maintenance
Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Provides management of the UPS via a serial port.Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Fast, easy installation takes the guesswork out of configuration for first-time users This LED informs users of potentially dangerous wiring problems in the wall circuit. Automatically cuts power to idle equipment to conserve electricity.Key selling points
- Compact size acommodates installation in a variety of environments
- Data line protection ensures complete protection of your equipment from surges
- LED display provides easy-to-read status of unit and utility power conditions
- Audible alarms provide notification of changing utility power and UPS power conditions
- Restore power backup capacity with user-replaceable battery (APCRBC110 sold separately)
- Compatible with PowerChute Serial Shutdown software for remote monitoring and management.